Utilize este link para identificar ou citar este item: https://bdm.unb.br/handle/10483/34594
Arquivos neste item:
Arquivo Descrição TamanhoFormato 
2020_ArturFiuzaBorgesArantes_tcc1.pdf925,14 kBAdobe PDFver/abrir
Título: Chemical and microbiological monitoring of biodiesel blend (B7) quality under simulated storage conditions
Autor(es): Arantes, Artur Fiuza Borges
Orientador(es): Batista, Pérola de Oliveira Magalhães Dias
Assunto: Biodiesel
Biocombustíveis
Data de apresentação: Dez-2020
Data de publicação: 24-Abr-2023
Referência: ARANTES, Artur Fiuza Borges. Chemical and microbiological monitoring of biodiesel blend (B7) quality under simulated storage conditions. 2020. 27 f., il. Trabalho de Conclusão de Curso (Bacharelado em Farmácia) — Universidade de Brasília, Brasília, 2020.
Abstract: Biodiesel is an oxygenated biofuel, and it has unsaturated carbon chains. It is more susceptible to oxidation, and because it is more hygroscopic than diesel, an increase in microbial contamination may also be favored. To study the biodiesel/diesel mixture's storage, a commercial sample of diesel B (B7 S500; 7% v / v biodiesel in diesel) was collected in a Center Western region station (Brazil) and stored in tanks. Lab analyses were performed for 90 days, the first time point being zero, and the following time points were taken every 30 days. Chemical analysis was performed using gas chromatography using methyl nonadecanoate as standard. Analysis of variance, with a probability of 95%, indicated that at 60 days of storage, the sample already presented chemical degradation. Microbial monitoring was performed and It was possible to distinguish four bacterial genera (Alkalihalobacillus, Bacillus, Paenibacillus, and Peribacillus) and at least 15 species. Fungi were isolated, and 17 genera were identified (32 species): Aspergillus, Cladosporium, Penicillium, Chaetomium, Curvularia, Epicoccum, Microascus, Paecilomyces, Acanthophysellum, Arthrinium, Bypolaris, Paraconiothyrium, Parengyodontium, Phlebiopsis, Polyporus, Talaromyces, and Xylaria. The isolation results showed a low level of contamination of the as-received B7 blend from the fuel station, which can be considered natural microbial contamination expected in a storage tank. The present study confirmed the contamination of B7 blend storage tanks by various microorganisms that can colonize and most likely degrade fuels and should be investigated in more detail as possible reference strains in biodeterioration studies.
Informações adicionais: Trabalho de Conclusão de Curso (graduação) — Universidade de Brasília, Faculdade de Ciências da Saúde, 2020.
Licença: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor que autoriza a Biblioteca Digital da Produção Intelectual Discente da Universidade de Brasília (BDM) a disponibilizar o trabalho de conclusão de curso por meio do sítio bdm.unb.br, com as seguintes condições: disponível sob Licença Creative Commons 4.0 International, que permite copiar, distribuir e transmitir o trabalho, desde que seja citado o autor e licenciante. Não permite o uso para fins comerciais nem a adaptação desta.
Aparece na Coleção:Farmácia - Campus Darcy Ribeiro



Todos os itens na BDM estão protegidos por copyright. Todos os direitos reservados.